HANNA Total Chlorine Handheld Colorimeter Checker (HI-711)
Key features
- Fully portable, fitting easily into both palm and pocket
- 0.00 to 3.50 ppm
- Checker®HC is supplied with reagents for 6 tests. Use code HI-711-25 (25 tests) for future purchases.
- High precision results - more accurate than chemical test kits
- Auto shut-off feature means the Checker cannot be left on by mistake
Supplied with
- 2 sample cuvettes
- Cuvette cap
- Starter pack of reagents x 6 (re-ordering information: HI-711-25 x 25 tests)
- 1 x 1.5 AAA battery
- Instructions
Specifications
| Range | 0.00 to 3.50 ppm | |
| Resolution | 0.01 ppm (mg/L) | |
| Precision | 3% of reading ±0.03 ppm (mg/L) @ 25°C | |
| Light Source | LED @ 525 nm | |
| Light Detector | Silicon photocell | |
| Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing | |
| Battery Type | (1) 1.5V AAA | |
| Auto-off | After 2 minutes of non-use and after reading | |
| Dimensions | 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”) | |
| Weight | 64 g (2.25 oz.) | |
| Method | EPA approved DPD method Standard Method 4500-Cl G. |
| PLEASE NOTE: | In some cases, samples may contain other parameters which may interfere with results | |
| Interference may be caused by: | Bromine, Iodine, Ozone, Oxidised forms of Chromium and Manganese. In case of water with hardness greater than 500 mg/L CaCO3, shake the sample for approximately 2 minutes after adding the powder reagent. If the water used for this procedure has an alkalinity value greater than 250 mg/L CaCO3 or acidity value greater than 150 mg/L CaCO3, the colour of the sample may develop only partially, or may rapidly fade. To resolve this, neutralise the sample with diluted HCl or NaOH. |
$26.98
Original: $89.95
-70%HANNA Total Chlorine Handheld Colorimeter Checker (HI-711)—
$89.95
$26.98




Description
Key features
- Fully portable, fitting easily into both palm and pocket
- 0.00 to 3.50 ppm
- Checker®HC is supplied with reagents for 6 tests. Use code HI-711-25 (25 tests) for future purchases.
- High precision results - more accurate than chemical test kits
- Auto shut-off feature means the Checker cannot be left on by mistake
Supplied with
- 2 sample cuvettes
- Cuvette cap
- Starter pack of reagents x 6 (re-ordering information: HI-711-25 x 25 tests)
- 1 x 1.5 AAA battery
- Instructions
Specifications
| Range | 0.00 to 3.50 ppm | |
| Resolution | 0.01 ppm (mg/L) | |
| Precision | 3% of reading ±0.03 ppm (mg/L) @ 25°C | |
| Light Source | LED @ 525 nm | |
| Light Detector | Silicon photocell | |
| Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing | |
| Battery Type | (1) 1.5V AAA | |
| Auto-off | After 2 minutes of non-use and after reading | |
| Dimensions | 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”) | |
| Weight | 64 g (2.25 oz.) | |
| Method | EPA approved DPD method Standard Method 4500-Cl G. |
| PLEASE NOTE: | In some cases, samples may contain other parameters which may interfere with results | |
| Interference may be caused by: | Bromine, Iodine, Ozone, Oxidised forms of Chromium and Manganese. In case of water with hardness greater than 500 mg/L CaCO3, shake the sample for approximately 2 minutes after adding the powder reagent. If the water used for this procedure has an alkalinity value greater than 250 mg/L CaCO3 or acidity value greater than 150 mg/L CaCO3, the colour of the sample may develop only partially, or may rapidly fade. To resolve this, neutralise the sample with diluted HCl or NaOH. |